ABS

6 min read · Updated

HERS to ECC: What Changed in 2026

For years, "HERS testing" was the phrase California contractors used for the third-party checks on new homes and HVAC changeouts. On January 1, 2026, with the 2025 Energy Code, the California Energy Commission moved that work into a new program called Energy Code Compliance, or ECC. The tests are largely the same. The names, the regulations behind them, and some of the rules are not.

📝 Educational reference

This summary follows the California Energy Commission's ECC Program pages. For a specific project, the Certificate of Compliance lists the verifications required.

What ECC Replaced

The Home Energy Rating System (HERS) program had two jobs: rating whole houses, and performing the field verification and diagnostic testing (FV&DT) that the Energy Code requires for compliance. The ECC Program takes over the second job. Its rules moved from Title 20 into the administrative section of Title 24, Part 1.

New Names

Before 2026 Under the 2025 Energy Code
HERS Provider ECC-Provider
HERS Rater ECC-Rater
HERS Rater company ECC-Rater Company
HERS verification ECC verification, or FV&DT
HERS Feature Summary on the CF1R ECC Feature Summary

All HERS raters were recognized as ECC-Raters on January 1, 2026, and HERS Providers had to apply for approval as ECC-Providers. Documents for projects under earlier code cycles still say HERS.

Who Provides ECC

ECC-Providers certify and oversee raters and operate the data registry where certificates are recorded. As of January 2026, the Energy Commission's counter sheet listed one approved ECC-Provider: CHEERS, approved on November 12, 2025, for newly constructed buildings, additions, and alterations. To find an ECC-Rater, the Commission directs people to the provider's website.

What Changed Besides the Names

Where ECC Applies

In multifamily buildings of four or more habitable stories, the installing contractors perform the required testing, except indoor air quality verification. Common ECC tests for HVAC are covered in Title 24 HVAC Changeout Testing.

ECC Is Not Acceptance Testing

The two programs are easy to confuse. ECC verification is done by independent raters, mainly on homes and dwelling units. Nonresidential mechanical acceptance testing is done by certified Acceptance Test Technicians, who may work for the installer. A firm can hold both certifications, but they are separate. See Acceptance Test Technician (ATT).

Sources

FAQ

Is HERS testing still required in California?+
The testing is, under a new name. Since January 1, 2026, the field verification and diagnostic testing that used to be called HERS testing is carried out under the Energy Code Compliance (ECC) Program by ECC-Raters. The tests themselves, such as duct leakage, airflow, fan efficacy, and refrigerant charge verification, are still required wherever the Energy Code calls for them.
What is an ECC-Rater?+
An ECC-Rater is a person certified by an approved ECC-Provider to perform field verification and diagnostic testing for Energy Code compliance. On January 1, 2026, all HERS raters were recognized as ECC-Raters. Rater companies are now called ECC-Rater Companies.
Who are the approved ECC-Providers?+
As of January 2026, the California Energy Commission listed CHEERS as the approved ECC-Provider for both newly constructed buildings and alterations. CHEERS was approved on November 12, 2025. Other organizations have applied, so check the Energy Commission's ECC-Provider page for the current list.
Does the HERS name still exist?+
Yes, in two places. Projects permitted under earlier code cycles keep their HERS documentation and terminology. And the whole-house Home Energy Rating System, which produces home energy ratings and audits, stays in the HERS program. Businesses may also keep "HERS" in their names; the Energy Commission does not regulate business names.
Which projects use ECC?+
Projects whose permit applications were submitted on or after January 1, 2026, and so fall under the 2025 Energy Code. Projects permitted earlier remain under the code cycle they were permitted under.